Please use this identifier to cite or link to this item: http://bura.brunel.ac.uk/handle/2438/17879
Title: Ankle joint position changes reliability of Ultrasound Tissue Characterisation in the Achilles tendon: A pilot study
Authors: Lawson, A
Noorkoiv, M
Masci, L
Mohagheghi, AA
Keywords: achilles tendon;reproducibility of results;tendinopathy;ultrasonography
Issue Date: 13-Sep-2019
Publisher: International Scientific Infromation
Citation: Lawson A. et al. (2019) 'Ankle Joint Position and the Reliability of Ultrasound Tissue Characterization of the Achilles Tendon: A Pilot Study', Medical science monitor, 25, pp. 6884 - 6893. doi: 10.12659/MSM.915685.
Abstract: BACKGROUND: Imaging of the Achilles tendon using ultrasound tissue characterization (UTC) involves taking up the slack of the tendon by including dorsiflexion of the ankle. This pilot study aimed to determine whether different longitudinal tension applied to the Achilles tendon during imaging affected the reliability of UTC. MATERIAL AND METHODS: Nine asymptomatic active volunteers, aged between 23-49 years underwent imaging of 17 Achilles tendons. Three positions of tension included plantar grade, 50%, and 100% of maximal dorsiflexion, with a range of 18-32°. Ranges were established and standardized using an isokinetic dynamometer. A test and re-test process was conducted at each position to determine the intraclass correlation coefficients (ICCs) and minimum detectable change (MDC) per echotype. Images were analyzed using UTC software. RESULTS: Plantar grade positioning images could not be obtained. ICCs for each echotype I-IV between test 1 and test 2 were 0.965, 0.962, 0.858, 0.739 at 100% dorsiflexion (95% CI, 0.86-0.99, 0.84-0.99, 0.51-0.97, and 0.2-0.94), and 0.771, 0.551, 0.569, 0.429 at 50% dorsiflexion (95% CI, 0.29-0.94, -0.09-0.88, -0.01-0.88, and -0.15-0.82). The MDC per echotype I-IV ranged between 4.1-1.0% of echotype data at 100% dorsiflexion, and 17.2-6.3% at 50% dorsiflexion. CONCLUSIONS: Testing at maximum dorsiflexion provided improved reliability when using UTC in healthy individuals. The ICC at 100% dorsiflexion was increased, and the MDC was reduced for all echotypes. Therefore, standardizing test positions when using UTC is advisable for reliable comparison of results between studies.
URI: https://bura.brunel.ac.uk/handle/2438/17879
DOI: https://doi.org/10.12659/MSM.915685
ISSN: 1234-1010
Appears in Collections:Dept of Life Sciences Research Papers
Dept of Health Sciences Research Papers

Files in This Item:
File Description SizeFormat 
FullText.pdfLawson A. et al.: Ankle joint position and the Achilles tendon © Med Sci Monit, 2019; 25: 6884-6893This work is licensed under Creative Common Attribution- NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0).1.08 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons