Please use this identifier to cite or link to this item: http://bura.brunel.ac.uk/handle/2438/14097
Title: Investigations into air and refrigerant side heat transfer coefficients of finned-tube CO2 gas coolers
Authors: Santosa, IMC
Gowreesunker, BL
Tassou, SA
Tsamos, KM
Ge, Y
Keywords: CO2 refrigeration systems;CO2 gas coolers;Air side heat transfer coefficient;Refrigeration side heat transfer coefficient;Modelling;Computational Fluid Dynamics (CFD)
Issue Date: 2017
Publisher: Elsevier
Citation: International Journal of Heat and Mass Transfer, 107: pp. 168 - 180, (2017)
Abstract: Gas coolers are heat rejection heat exchangers in vapour compression refrigeration systems that use carbon dioxide (CO2) as refrigerant. The design of gas coolers has a significant influence on the performance of CO2 refrigeration systems as it determines to a large extent the gas cooler/condenser pressure and the power consumption of the system. This paper investigates local refrigerant and air heat transfer coefficients in plain fin-and-tube gas cooler coils using Computational Fluid Dynamics (CFD) modelling. The aims were to provide insights into the variation of the local heat transfer rates in the coil and determine the influence of a) design enhancements such as the use of slit fins and b) to develop correlations for overall refrigerant and air heat transfer coefficients to be used in CO2 refrigeration component and system modelling. The results from the model which was validated against experimental measurements showed that a horizontal slit on the fin between the first and second row of tubes can lead to an increase in the heat rejection rate of the gas cooler by between 6% and 8%. This in turn can lead to smaller heat exchanger heat transfer area for a given heat rejection capacity or lower high side pressure and higher efficiency for the refrigeration system. The results and heat transfer correlations developed are a valuable resource for researchers and manufacturers of CO2 and other heat exchanger coils that experience a wide variation in refrigerant temperature during the gas cooling process.
URI: http://bura.brunel.ac.uk/handle/2438/14097
DOI: http://dx.doi.org/10.1016/j.ijheatmasstransfer.2016.11.011
ISSN: 0017-9310
Appears in Collections:Dept of Mechanical and Aerospace Engineering Research Papers

Files in This Item:
File Description SizeFormat 
FullText.pdf4.02 MBAdobe PDFView/Open


Items in BURA are protected by copyright, with all rights reserved, unless otherwise indicated.