Please use this identifier to cite or link to this item: http://bura.brunel.ac.uk/handle/2438/14097
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSantosa, IMC-
dc.contributor.authorGowreesunker, BL-
dc.contributor.authorTassou, SA-
dc.contributor.authorTsamos, KM-
dc.contributor.authorGe, Y-
dc.date.accessioned2017-02-22T16:03:48Z-
dc.date.available2017-04-
dc.date.available2017-02-22T16:03:48Z-
dc.date.issued2017-
dc.identifier.citationInternational Journal of Heat and Mass Transfer, 107: pp. 168 - 180, (2017)en_US
dc.identifier.issn0017-9310-
dc.identifier.urihttp://bura.brunel.ac.uk/handle/2438/14097-
dc.description.abstractGas coolers are heat rejection heat exchangers in vapour compression refrigeration systems that use carbon dioxide (CO2) as refrigerant. The design of gas coolers has a significant influence on the performance of CO2 refrigeration systems as it determines to a large extent the gas cooler/condenser pressure and the power consumption of the system. This paper investigates local refrigerant and air heat transfer coefficients in plain fin-and-tube gas cooler coils using Computational Fluid Dynamics (CFD) modelling. The aims were to provide insights into the variation of the local heat transfer rates in the coil and determine the influence of a) design enhancements such as the use of slit fins and b) to develop correlations for overall refrigerant and air heat transfer coefficients to be used in CO2 refrigeration component and system modelling. The results from the model which was validated against experimental measurements showed that a horizontal slit on the fin between the first and second row of tubes can lead to an increase in the heat rejection rate of the gas cooler by between 6% and 8%. This in turn can lead to smaller heat exchanger heat transfer area for a given heat rejection capacity or lower high side pressure and higher efficiency for the refrigeration system. The results and heat transfer correlations developed are a valuable resource for researchers and manufacturers of CO2 and other heat exchanger coils that experience a wide variation in refrigerant temperature during the gas cooling process.en_US
dc.description.sponsorshipThis study was supported by the RCUK National Centre for Sustainable Energy use in Food chains (CSEF) of the Research CouncilsUK Energy programme, Grant No: EP/K011820/1, GEA Searle, now Kevlion, and Directorate General for Higher Education-DIKTI–Indonesian Government for a PhD scholarship.en_US
dc.format.extent168 - 180-
dc.language.isoenen_US
dc.publisherElsevieren_US
dc.subjectCO2 refrigeration systemsen_US
dc.subjectCO2 gas coolersen_US
dc.subjectAir side heat transfer coefficienten_US
dc.subjectRefrigeration side heat transfer coefficienten_US
dc.subjectModellingen_US
dc.subjectComputational Fluid Dynamics (CFD)en_US
dc.titleInvestigations into air and refrigerant side heat transfer coefficients of finned-tube CO2 gas coolersen_US
dc.typeArticleen_US
dc.identifier.doihttp://dx.doi.org/10.1016/j.ijheatmasstransfer.2016.11.011-
dc.relation.isPartOfInternational Journal of Heat and Mass Transfer-
pubs.publication-statusAccepted-
pubs.volume107-
Appears in Collections:Dept of Mechanical and Aerospace Engineering Research Papers

Files in This Item:
File Description SizeFormat 
FullText.pdf4.02 MBAdobe PDFView/Open


Items in BURA are protected by copyright, with all rights reserved, unless otherwise indicated.