Please use this identifier to cite or link to this item: http://bura.brunel.ac.uk/handle/2438/13523
Full metadata record
DC FieldValueLanguage
dc.contributor.authorKolokotroni, M-
dc.contributor.authorO'Sullivan, P-
dc.date.accessioned2016-11-21T12:01:57Z-
dc.date.available2016-11-21T12:01:57Z-
dc.date.issued2016-
dc.identifier.citationEnergy and Buildings, (2016)en_US
dc.identifier.issn1872-6178-
dc.identifier.urihttp://bura.brunel.ac.uk/handle/2438/13523-
dc.description.abstractAn increasingly popular solution for ventilation that facilitates strategies such as night cooling is the provision of purpose provided ventilation openings comprised of horizontal slotted architectural louvres. Often these are employed in single sided ventilation strategies where there exists an irregular unsteady interaction of wind and buoyancy forces. This paper presents results from full scale experimental measurements of the macroscopic Air Change Rate (ACR) for an opening utilising an architectural slotted louvre in zero2020/NBERT, a National Building Energy Retrofit Testbed in Cork, Ireland. 2 slot louvre cases and 3 plain opening cases were investigated with 44 tracer gas concentration decay tests completed in a single cell isolated office space. The findings show that, for similar boundary conditions, the spectral characteristics of the velocity in the opening are modified by the introduction of the Slot Louvre. A non-dimensional analysis highlights stronger wind dominant aeration for the louvre than a plain opening having comparable overall facade opening dimensions. On average across the various cases measured, the slot louvre ACR were 6.5% higher compared with the plain opening ACR with even greater increases when considering comparable free opening area cases specifically. A sensitivity analysis using stepwise multiple linear regression also demonstrated a high correlation between ACR, wind speed and wind direction for the Slot Louvre. A comparison of existing single sided correlations showed lower prediction error for the plain opening cases than for the slot louvre. When considering the dimensionless exchange rate parameter, Fr20 , the published values for plain openings was comparable to those in this study but were too low in general for the slot louvre. An alternative value for this is suggested based on the field study measurements.en_US
dc.language.isoenen_US
dc.publisherElsevieren_US
dc.subjectZero2020/NBERTen_US
dc.subjectSlot louvreen_US
dc.subjectField studyen_US
dc.subjectMacroscopic ACRen_US
dc.subjectDimensionless exchange rateen_US
dc.subjectSingle sideden_US
dc.titleA field study of wind dominant single sided ventilation through a narrow slotted architectural louvre systemen_US
dc.typeArticleen_US
dc.relation.isPartOfEnergy and Buildings-
pubs.publication-statusAccepted-
Appears in Collections:Dept of Mechanical and Aerospace Engineering Research Papers

Files in This Item:
File Description SizeFormat 
Fulltext.pdf2.66 MBAdobe PDFView/Open


Items in BURA are protected by copyright, with all rights reserved, unless otherwise indicated.