Please use this identifier to cite or link to this item: http://bura.brunel.ac.uk/handle/2438/9393
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPapadopoulos, VE-
dc.contributor.authorKefala, IK-
dc.contributor.authorKokkoris, G-
dc.contributor.authorTserepi, A-
dc.contributor.author4th Micro and Nano Flows Conference (MNF2014)-
dc.date.accessioned2014-12-05T12:51:32Z-
dc.date.available2014-12-05T12:51:32Z-
dc.date.issued2014-
dc.identifier.citation4th Micro and Nano Flows Conference, University College London, UK, 7-10 September 2014, Editors CS König, TG Karayiannis and S. Balabanien_US
dc.identifier.isbn978-1-908549-16-7-
dc.identifier.urihttp://bura.brunel.ac.uk/handle/2438/9393-
dc.descriptionThis paper was presented at the 4th Micro and Nano Flows Conference (MNF2014), which was held at University College, London, UK. The conference was organised by Brunel University and supported by the Italian Union of Thermofluiddynamics, IPEM, the Process Intensification Network, the Institution of Mechanical Engineers, the Heat Transfer Society, HEXAG - the Heat Exchange Action Group, and the Energy Institute, ASME Press, LCN London Centre for Nanotechnology, UCL University College London, UCL Engineering, the International NanoScience Community, www.nanopaprika.eu.en_US
dc.description.abstractTwo types of μPCR devices, a continuous flow and a static chamber device, fabricated on flexible polymeric substrates are compared in the current computational study. Laminar flow, heat transfer in both solid and fluid, mass conservation of species, and reaction kinetics of PCR are coupled using COMSOL. The comparison is performed under same conditions; same material stack (based on flexible polymeric films with integrated microheaters), same species initial concentrations, amplification of the same volume of fluid sample, and implementation of the same PCR protocol. Performance is quantified in terms of DNA amplification, energy consumption, and total operating time. The calculations show that the efficiency of DNA amplification is higher in the continuous flow device. However, the continuous flow device requires (~6 times) greater energy consumption which is justified by the smaller thermal mass of the static chamber device. As regards the speed, the total time required for the static chamber μPCR is comparable to the time for the continuous flow μPCR.en_US
dc.language.isoenen_US
dc.publisherBrunel University Londonen_US
dc.relation.ispartofseriesID 153-
dc.subjectMicroflowen_US
dc.subjectHeat transferen_US
dc.subjectPCRen_US
dc.subjectMicrofluidicsen_US
dc.subjectDNA Amplificationen_US
dc.subjectContinuous flowen_US
dc.subjectStatic chamberen_US
dc.subjectμTASen_US
dc.subjectLoCen_US
dc.subjectFlexible substratesen_US
dc.titleContinuous Flow vs. Static Chamber μPCR Devices on Flexible Polymeric Substratesen_US
dc.typeConference Paperen_US
Appears in Collections:Brunel Institute for Bioengineering (BIB)
The Brunel Collection



Items in BURA are protected by copyright, with all rights reserved, unless otherwise indicated.