Please use this identifier to cite or link to this item: http://bura.brunel.ac.uk/handle/2438/9107
Full metadata record
DC FieldValueLanguage
dc.contributor.authorBurugapalli, K-
dc.contributor.authorChan, JCY-
dc.contributor.authorKelly, JL-
dc.contributor.authorPandit, A-
dc.date.accessioned2014-09-16T15:59:17Z-
dc.date.available2014-09-16T15:59:17Z-
dc.date.issued2008-
dc.identifier.citationObesity Surgery, 18(11), 1418 - 1423, 2008en_US
dc.identifier.issn0960-8923-
dc.identifier.urihttp://link.springer.com/article/10.1007%2Fs11695-008-9518-7en
dc.identifier.urihttp://bura.brunel.ac.uk/handle/2438/9107-
dc.descriptionThis is the author's accepted manuscript. The final published article is available from the link below. Copyright @ Springer Science + Business Media, LLC 2008en_US
dc.description.abstractBackground - Staple line leakage and bleeding are the most common problems associated with the use of surgical staplers for gastrointestinal resection and anastomotic procedures. These complications can be reduced by reinforcing the staple lines with buttressing materials. The current study reports the potential use of cholecyst-derived extracellular matrix (CEM) in non-crosslinked (NCEM) and crosslinked (XCEM) forms, and compares their mechanical performance with clinically available buttress materials [small intestinal submucosa (SIS) and bovine pericardium (BP)] in an ex vivo small intestine model. Methods - Three crosslinked CEM variants (XCEM0005, XCEM001, and XCEM0033) with different degree of crosslinking were produced. An ex vivo peristaltic inflation model was established. Porcine small intestine segments were stapled on one end, using buttressed or non-buttressed surgical staplers. The opened, non-stapled ends were connected to a peristaltic pump and pressure transducer and sealed. The staple lines were then exposed to increased intraluminal pressure in a peristaltic manner. Both the leak and burst pressures of the test specimens were recorded. Results - The leak pressures observed for non-crosslinked NCEM (137.8 ± 22.3 mmHg), crosslinked XCEM0005 (109.1 ± 14.1 mmHg), XCEM001 (150.1 ± 16.0 mmHg), XCEM0033 (98.8 ± 10.5 mmHg) reinforced staple lines were significantly higher when compared to non-buttressed control (28.3 ± 10.8 mmHg) and SIS (one and four layers) (62.6 ± 11.8 and 57.6 ± 12.3 mmHg, respectively) buttressed staple lines. NCEM and XCEM were comparable to that observed for BP buttressed staple lines (138.8 ± 3.6 mmHg). Only specimens with reinforced staple lines were able to achieve high intraluminal pressures (ruptured at the intestinal mesentery), indicating that buttress reinforcements were able to withstand pressure higher than that of natural tissue (physiological failure). Conclusions - These findings suggest that the use of CEM and XCEM as buttressing materials is associated with reinforced staple lines and increased leak pressures when compared to non-buttressed staple lines. CEM and XCEM were found to perform comparably with clinically available buttress materials in this ex vivo model.en_US
dc.description.sponsorshipEnterprise Irelanden_US
dc.languageEnglish-
dc.language.isoenen_US
dc.publisherSpringeren_US
dc.subjectStaple line reinforcementen_US
dc.subjectButtressen_US
dc.subjectCholecyst-derived extracellular matrixen_US
dc.subjectEx-vivoen_US
dc.subjectLinear stapleren_US
dc.titleButtressing staples with cholecyst-derived extracellular matrix (CEM) reinforces staple lines in an ex vivo peristaltic inflation modelen_US
dc.typeArticleen_US
dc.identifier.doihttp://dx.doi.org/10.1007/s11695-008-9518-7-
pubs.organisational-data/Brunel-
pubs.organisational-data/Brunel/Brunel Staff by College/Department/Division-
pubs.organisational-data/Brunel/Brunel Staff by College/Department/Division/College of Engineering, Design and Physical Sciences-
pubs.organisational-data/Brunel/Brunel Staff by College/Department/Division/College of Engineering, Design and Physical Sciences/Dept of Mechanical, Aerospace and Civil Engineering-
pubs.organisational-data/Brunel/Brunel Staff by College/Department/Division/College of Engineering, Design and Physical Sciences/Dept of Mechanical, Aerospace and Civil Engineering/Mechanical and Aerospace Engineering-
pubs.organisational-data/Brunel/Brunel Staff by Institute/Theme-
pubs.organisational-data/Brunel/Brunel Staff by Institute/Theme/Institute of Environmental, Health and Societies-
pubs.organisational-data/Brunel/Brunel Staff by Institute/Theme/Institute of Environmental, Health and Societies/Biomedical Engineering and Healthcare Technologies-
pubs.organisational-data/Brunel/University Research Centres and Groups-
pubs.organisational-data/Brunel/University Research Centres and Groups/School of Health Sciences and Social Care - URCs and Groups-
pubs.organisational-data/Brunel/University Research Centres and Groups/School of Health Sciences and Social Care - URCs and Groups/Brunel Institute for Ageing Studies-
Appears in Collections:Brunel Institute for Bioengineering (BIB)
Dept of Mechanical and Aerospace Engineering Research Papers

Files in This Item:
File Description SizeFormat 
Fulltext.pdf521.85 kBAdobe PDFView/Open


Items in BURA are protected by copyright, with all rights reserved, unless otherwise indicated.