Please use this identifier to cite or link to this item: http://bura.brunel.ac.uk/handle/2438/6835
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSoulis, JV-
dc.contributor.authorSeralidou, KV-
dc.contributor.authorChatzizisis, YS-
dc.contributor.authorGiannoglou, GD-
dc.contributor.author3rd Micro and Nano Flows Conference (MNF2011)-
dc.date.accessioned2012-10-02T10:11:29Z-
dc.date.available2012-10-02T10:11:29Z-
dc.date.issued2011-
dc.identifier.citation3rd Micro and Nano Flows Conference, Thessaloniki, Greece, 22-24 August 2011en_US
dc.identifier.isbn978-1-902316-98-7-
dc.identifier.urihttp://bura.brunel.ac.uk/handle/2438/6835-
dc.descriptionThis paper was presented at the 3rd Micro and Nano Flows Conference (MNF2011), which was held at the Makedonia Palace Hotel, Thessaloniki in Greece. The conference was organised by Brunel University and supported by the Italian Union of Thermofluiddynamics, Aristotle University of Thessaloniki, University of Thessaly, IPEM, the Process Intensification Network, the Institution of Mechanical Engineers, the Heat Transfer Society, HEXAG - the Heat Exchange Action Group, and the Energy Institute.en_US
dc.description.abstractThe capabilities and limitations of various molecular viscosity models, when testing Left Coronary Artery (LCA) tree, were analyzed via: molecular viscosity, local and global non-Newtonian importance factors, Wall Shear Stress (WSS) and Wall Shear Stress Gradient (WSSG). Seven non-Newtonian molecular viscosity models, plus the Newtonian one, were compared. Dense grid of 620000 nodes located, mostly, at near to low WSS flow regions (endothelium regions) is needed for current LCA application. The WSS distribution yields a consistent LCA pattern for nearly all non-Newtonian models. High molecular viscosity, low WSS low WSSG values appear at proximal LCA regions at the outer walls of the major bifurcation. The global importance factor for the non-Newtonian power law model yields 76.7% (non-Newtonian flow), while for the Generalized power law model this value is 6.1% (Newtonian flow). The capabilities of the applied non-Newtonian law models appear at low strain rates. The Newtonian blood flow treatment is considered to be a good approximation at mid-and high-strain rates. In general, the non-Newtonian power law and the Generalized power law blood viscosity models are considered to approximate the molecular viscosity and WSS calculations in a more satisfactory way.en_US
dc.language.isoenen_US
dc.publisherBrunel Universityen_US
dc.subjectNon-Newtonian blood flowen_US
dc.subjectImportance factoren_US
dc.subjectSeverity parameteren_US
dc.subjectCoronary arteryen_US
dc.titleSeverity parameter and global importance factor of non-newtonian models in 3D reconstructed human left coronary arteryen_US
dc.typeConference Paperen_US
Appears in Collections:Brunel Institute for Bioengineering (BIB)
The Brunel Collection

Files in This Item:
File Description SizeFormat 
MNF2011.pdf1.1 MBAdobe PDFView/Open


Items in BURA are protected by copyright, with all rights reserved, unless otherwise indicated.