Please use this identifier to cite or link to this item: http://bura.brunel.ac.uk/handle/2438/28800
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGunaratna Mudiyanselage, NH-
dc.contributor.authorHobson, P-
dc.contributor.authorSmith, D-
dc.coverage.spatialMilan, Italy-
dc.date.accessioned2024-04-18T15:00:38Z-
dc.date.available2024-04-18T15:00:38Z-
dc.date.issued2022-11-07-
dc.identifierORCiD: Peter R. Hobson https://orcid.org/0000-0002-5645-5253-
dc.identifierORCiD: David R. Smith https://orcid.org/0000-0003-3658-4506-
dc.identifier.citationGunaratna Mudiyanselage, N.H., Hobson. P.R. and Smith, D.R. (2022) Determination of energy resolution for YSO:Ce detector modelled with FLUKA code [Poster]. Exhibited at 2022 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 7 November. 60cm x 84 cm.en_US
dc.identifier.urihttps://bura.brunel.ac.uk/handle/2438/28800-
dc.descriptionConference poster presented at 2022 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), Milan, Italy, 7 November, 2022.en_US
dc.description.abstractConclusion: In this study, a 5 x 5 x 5 mm 3 YSO Ce detector was modelled using the FLUKA code The pulse height distributions of the detector were obtained for each point gamma source in the energy range 59 keV 662 keV, and the energy resolution was calculated It was observed that relative percentage differences between the experimental and simulation results are within 10 This study showed that the FLUKA code also can be used to determine the energy resolution and can therefore be of benefit in terms of reducing financial cost and time in the development of new scintillators and radiation sensors.en_US
dc.description.sponsorshipThis work was performed as a part of Ph.D. project funded under EPSRC DTP grant EP/T518116/1. The authors would like to thank EPSRC for financial support, and Brunel University London for facilitating this research.en_US
dc.language.isoen_USen_US
dc.publisherIEEEen_US
dc.source2022 IEEE Nuclear Science Symposium and Medical Imaging Conference-
dc.source2022 IEEE Nuclear Science Symposium and Medical Imaging Conference-
dc.titleDetermination of energy resolution for YSO:Ce detector modelled with FLUKA codeen_US
dc.typeOtheren_US
pubs.finish-date2022-11-07-
pubs.start-date2022-11-07-
Appears in Collections:Dept of Electronic and Electrical Engineering Research Papers

Files in This Item:
File Description SizeFormat 
Poster.pdf354.23 kBAdobe PDFView/Open


Items in BURA are protected by copyright, with all rights reserved, unless otherwise indicated.