Please use this identifier to cite or link to this item: http://bura.brunel.ac.uk/handle/2438/28185
Title: Effectiveness of Fan Anchors in Preventing Debonding in FRP-Strengthened Steel Members
Authors: Esmaeeli, E
Shadan, P
Keywords: debonding;fan anchor;FRP-strengthening;steel structures;FE modelling
Issue Date: 21-Oct-2022
Publisher: Springer Nature
Citation: Esmaeeli, E. and Shadan, P. (2022) 'Effectiveness of Fan Anchors in Preventing Debonding in FRP-Strengthened Steel Members', International Journal of Steel Structures, 23 (1), pp. 96 - 119. doi: 10.1007/s13296-022-00681-4.
Abstract: Copyright © The Author(s) 2022. Fibre Reinforced Polymers (FRPs) are extensively employed to strengthen existing structures because of their several advantages over other strengthening techniques. On the other hand, the premature debonding of FRP reduces its effectiveness in strengthening steel structures. Anchoring FRP composites is an effective solution to delay or even prevent their debonding. Very limited anchorage methods, however, have been introduced for FRP-strengthened steel structures and the need for an effective anchorage system remains. Fan anchor has been validated as one of the remedies against debonding failure in FRP-strengthened concrete structures. Considering the advantages that fan anchors offer, the use of fan anchors for FRP-strengthened steel structures is proposed and evaluated in this paper. Since FRP-steel joints have a different bond-slip law than FRP-concrete joints and the strengthened steel members are prone to buckling-debonding interactions, this study focuses on the efficiency of fan anchors in delaying FRP debonding by assuming that an adequate mechanical connection between the dowel and the steel substrate is provided. Three experimental studies involving shear, flexural and buckling strengthening of steel components were simulated through finite element modelling, and fan anchors were added to the models after validation. The effect of fan anchors on strength, failure mode and FRP's strain distribution of the models was examined. The study showed that the fan anchor was successfully able to delay debonding mode, which increased the strength and ductility and exploited a higher strain capacity of FRP plates.
URI: https://bura.brunel.ac.uk/handle/2438/28185
DOI: https://doi.org/10.1007/s13296-022-00681-4
ISSN: 1598-2351
Other Identifiers: ORCID iD: Esmaeel Esmaeeli https://orcid.org/0000-0003-2332-8087
Appears in Collections:Dept of Civil and Environmental Engineering Research Papers

Files in This Item:
File Description SizeFormat 
FullText.pdfCopyright © The Author(s) 2022. Rights and permissions: Open Access. This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit https://creativecommons.org/licenses/by/4.0/.5.48 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons