Please use this identifier to cite or link to this item: http://bura.brunel.ac.uk/handle/2438/27191
Full metadata record
DC FieldValueLanguage
dc.contributor.authorLee, VYS-
dc.contributor.authorKarayiannis, TG-
dc.date.accessioned2023-09-14T16:28:20Z-
dc.date.available2023-09-14T16:28:20Z-
dc.date.issued2023-07-07-
dc.identifierORCID iDs: Vivian Y.S. Lee https://orcid.org/0000-0002-5239-7762; Tassos G Karayiannis https://orcid.org/0000-0002-5225-960X.-
dc.identifier124470-
dc.identifier.citationLee, V.Y.S. and Karayiannis, T.G. (2023) 'Influence of system pressure on flow boiling in microchannels', International Journal of Heat and Mass Transfer, 215, 124470, pp. 1 - 13. doi: 10.1016/j.ijheatmasstransfer.2023.124470.en_US
dc.identifier.issn0017-9310-
dc.identifier.urihttps://bura.brunel.ac.uk/handle/2438/27191-
dc.descriptionData availability: Data will be made available on request.en_US
dc.descriptionThe authors would like to acknowledge the support of CPI TMD Technologies Division (formerly TMD Technologies Ltd.) and Mr Costas Xanthos of the Two-Phase Flow and Heat Transfer Group at Brunel University London for this work.-
dc.description.abstractCopyright © 2023 The Authors. The effect of pressure on the flow boiling characteristics of HFE-7200 between 1.0 to 2.0 bar was investigated in a parallel microchannel heat sink (Dh = 0.48 mm, 44 channels). The mass flux and subcooling degree were kept constant at 200 kg/m2 s and 10 K respectively, while heat flux ranged from 26.1 – 160.7 kW/m2. Increasing system pressure decreased the vapour density ratio, thus leading to reduced pressure drop, increased bubble generation frequency and two-phase heat transfer coefficients in the system, though this may not be apparent at low superheat degrees at higher pressures. Smaller bubble diameters were observed at higher pressures and resulted in a delay in flow regime transition to slug flow, which is prone to flow reversal. The experimental work showed promising means to manage flow instabilities and enhance heat transfer performance in two-phase microchannel systems for HFE-7200.en_US
dc.format.extent1 - 13-
dc.format.mediumPrint-Electronic-
dc.languageEnglish-
dc.language.isoen_USen_US
dc.publisherElsevieren_US
dc.rightsCopyright © 2023 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY license (https://creativecommons.org/licenses/by/4.0/).-
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/-
dc.subjectsystem pressureen_US
dc.subjectmicrochannelen_US
dc.subjecttwo-phaseen_US
dc.subjectheat transferen_US
dc.titleInfluence of system pressure on flow boiling in microchannelsen_US
dc.typeArticleen_US
dc.identifier.doihttps://doi.org/10.1016/j.ijheatmasstransfer.2023.124470-
dc.relation.isPartOfInternational Journal of Heat and Mass Transfer-
pubs.publication-statusPublished online-
pubs.volume215-
dc.identifier.eissn1879-2189-
dc.rights.holderThe Authors-
Appears in Collections:Dept of Mechanical and Aerospace Engineering Research Papers

Files in This Item:
File Description SizeFormat 
FullText.pdfCopyright © 2023 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY license (https://creativecommons.org/licenses/by/4.0/).3.56 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons