Please use this identifier to cite or link to this item: http://bura.brunel.ac.uk/handle/2438/24727
Title: Real-Time Data-Driven Approach for Prediction and Correction of Electrode Array Trajectory in Cochlear Implantation
Authors: Hafeez, N
Du, X
Boulgouris, N
Begg, P
Irving, R
Coulson, C
Tourrel, G
Keywords: complex bipolar impedance;electrode array trajectory;classifier-in-a-loop;machine intelligence
Issue Date: 22-Jun-2022
Publisher: MDPI AG
Citation: Hafeez, N., Du, X., Boulgouris, N., Begg, P., Irving, R., Coulson, C. and Tourrel, G. (2022) 'Real-Time Data-Driven Approach for Prediction and Correction of Electrode Array Trajectory in Cochlear Implantation', Applied Sciences, 12 (13), 6343, pp. 1-14. doi: 10.3390/app12136343.
Abstract: Copyright: © 2022 by the authors. Cochlear implants provide hearing perception to people with severe to profound hearing loss. The electrode array (EA) inserted during the surgery directly stimulates the hearing nerve, bypassing the acoustic hearing system. The complications during the EA insertion in the inner ear may cause trauma leading to infection, residual hearing loss, and poor speech perception. This work aims to reduce the trauma induced during electrode array insertion process by carefully designing a sensing method, an actuation system, and data-driven control strategy to guide electrode array in scala tympani. Due to limited intra-operative feedback during the insertion process, complex bipolar electrical impedance is used as a sensing element to guide EA in real time. An automated actuation system with three degrees of freedom was used along with a complex impedance meter to record impedance of consecutive electrodes. Prediction of EA direction (medial, middle, and lateral) was carried out by an ensemble of random forest, shallow neural network, and k-nearest neighbour in an offline setting with an accuracy of 86.86%. The trained ensemble was then utilized in vitro for prediction and correction of EA direction in real time in the straight path with an accuracy of 80%. Such a real-time system also has application in other electrode implants and needle and catheter insertion guidance.
Description: Data Availability Statement: Not applicable.
URI: https://bura.brunel.ac.uk/handle/2438/24727
DOI: https://doi.org/10.3390/app12136343
Other Identifiers: 6343
Appears in Collections:Dept of Mechanical and Aerospace Engineering Research Papers

Files in This Item:
File Description SizeFormat 
FullText.pdf891.65 kBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons