Please use this identifier to cite or link to this item: http://bura.brunel.ac.uk/handle/2438/24610
Title: Non-Invasive Hemodynamics Monitoring System Based on Electrocardiography via Deep Convolutional Autoencoder
Authors: Sadrawi, M
Lin, YT
Lin, CH
Mathunjwa, B
Hsin, HT
Fan, SZ
Abbod, MF
Shieh, JS
Keywords: non-invasive system;hemodynamics;electrocardiography;arterial blood pressure;central venous pressure;pulmonary arterial pressure;intracranial pressure;deep convolutional autoencoder
Issue Date: 18-Sep-2021
Publisher: MDPI AG
Citation: Sadrawi, M., Lin, Y.T., Lin, C.H., Mathunjwa, B., Hsin, H.T., Fan, S.Z., Abbod, M.F. and Shieh, J.S. (2021) ‘Non-Invasive Hemodynamics Monitoring System Based on Electrocardiography via Deep Convolutional Autoencoder’, Sensors, 21 (18), 6264, pp. 1-20. doi: 10.3390/s21186264.
Abstract: Copyright: © 2021 by the authors. This study evaluates cardiovascular and cerebral hemodynamics systems by only using non-invasive electrocardiography (ECG) signals. The Massachusetts General Hospital/Marquette Foundation (MGH/MF) and Cerebral Hemodynamic Autoregulatory Information System Database (CHARIS DB) from the PhysioNet database are used for cardiovascular and cerebral hemodynamics, respectively. For cardiovascular hemodynamics, the ECG is used for generating the arterial blood pressure (ABP), central venous pressure (CVP), and pulmonary arterial pressure (PAP). Meanwhile, for cerebral hemodynamics, the ECG is utilized for the intracranial pressure (ICP) generator. A deep convolutional autoencoder system is applied for this study. The cross-validation method with Pearson's linear correlation (R), root mean squared error (RMSE), and mean absolute error (MAE) are measured for the evaluations. Initially, the ECG is used to generate the cardiovascular waveform. For the ABP system-the systolic blood pressure (SBP) and diastolic blood pressures (DBP)-the R evaluations are 0.894 ± 0.004 and 0.881 ± 0.005, respectively. The MAE evaluations for SBP and DBP are, respectively, 6.645 ± 0.353 mmHg and 3.210 ± 0.104 mmHg. Furthermore, for the PAP system-the systolic and diastolic pressures-the R evaluations are 0.864 ± 0.003 mmHg and 0.817 ± 0.006 mmHg, respectively. The MAE evaluations for systolic and diastolic pressures are, respectively, 3.847 ± 0.136 mmHg and 2.964 ± 0.181 mmHg. Meanwhile, the mean CVP evaluations are 0.916 ± 0.001, 2.220 ± 0.039 mmHg, and 1.329 ± 0.036 mmHg, respectively, for R, RMSE, and MAE. For the mean ICP evaluation in cerebral hemodynamics, the R and MAE evaluations are 0.914 ± 0.003 and 2.404 ± 0.043 mmHg, respectively. This study, as a proof of concept, concludes that the non-invasive cardiovascular and cerebral hemodynamics systems can be potentially investigated by only using the ECG signal.
Description: Data Availability Statement: This study utilizes the publicly available dataset, from https://physionet.org, accessed on 14 January 2021.
URI: https://bura.brunel.ac.uk/handle/2438/24610
DOI: https://doi.org/10.3390/s21186264
Other Identifiers: 6264
Appears in Collections:Dept of Electronic and Electrical Engineering Research Papers

Files in This Item:
File Description SizeFormat 
FullTime.pdf4.51 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons