Please use this identifier to cite or link to this item: http://bura.brunel.ac.uk/handle/2438/23343
Title: Transfer-function free technique for the non-invasive determination of the human arterial pressure waveform
Authors: Giudici, A
Palombo, C
Morizzo, C
Kozakova, M
Cruickshank, JK
Wilkinson, IB
Khir, AW
Keywords: carotid artery;hypertension;local wave speed;noninvasive estimation of pressure;pressure
Issue Date: 22-Sep-2021
Publisher: Wiley on behalf of The Physiological Society and the American Physiological Society
Citation: Giudici, A., Palombo, C., Morizzo, C., Kozakova, M., Cruickshank, J.K., Wilkinson, I.B. and Khir, A.W. (2021) 'Transfer-function-free technique for the noninvasive determination of the human arterial pressure waveform', Physiological Reports, 9 (18), e15040, pp. 1-12. doi: 10.14814/phy2.15040.
Abstract: © 2021 The Authors. The estimation of central aortic blood pressure is a cardinal measurement, carrying effective physiological, and prognostic data beyond routine peripheral blood pressure. Transfer function-based devices effectively estimate aortic systolic and diastolic blood pressure from peripheral pressure waveforms, but the reconstructed pressure waveform seems to preserve features of the peripheral waveform. We sought to develop a new method for converting the local diameter distension waveform into a pressure waveform, through an exponential function whose parameters depend on the local wave speed. The proposed method was then tested at the common carotid artery. Diameter and blood velocity waveforms were acquired via ultrasound at the right common carotid artery while simultaneously recording pressure at the left common carotid artery via tonometer in 203 people (122 men, 50 ± 18 years). The wave speed was noninvasively estimated via the lnDU-loop method and then used to define the exponential function to convert the diameter into pressure. Noninvasive systolic and mean pressures estimated by the new technique were 3.8 ± 21.8 (p = 0.015) and 2.3 ± 9.6 mmHg (p = 0.011) higher than those obtained using tonometery. However, differences were much reduced and not significant in people >35 years (0.6 ± 18.7 and 0.8 ± 8.3 mmHg, respectively). This proof of concept study demonstrated that local wave speed, estimated from noninvasive local measurement of diameter and flow velocity, can be used to determine an exponential function that describes the relationship between local pressure and diameter. This pressure-diameter function can then be used for the noninvasive estimation of local arterial pressure.
URI: https://bura.brunel.ac.uk/handle/2438/23343
DOI: https://doi.org/10.14814/phy2.15040
Other Identifiers: e15040
Appears in Collections:Brunel Institute for Bioengineering (BIB)
Dept of Mechanical and Aerospace Engineering Research Papers

Files in This Item:
File Description SizeFormat 
FullText.pdf1.26 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons