Please use this identifier to cite or link to this item: http://bura.brunel.ac.uk/handle/2438/22249
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAtes, AM-
dc.contributor.authorSingh, H-
dc.date.accessioned2021-02-10T14:26:35Z-
dc.date.available2021-02-10T14:26:35Z-
dc.date.issued2021-02-10-
dc.identifier101361-
dc.identifier.citationAtes, A.M. and Singh, H. (2021) 'Rooftop solar Photovoltaic (PV) plant – one year measured performance and simulations', Journal of King Saud University - Science, 33 (3), 101361, pp. 1 - 18. doi: 10.1016/j.jksus.2021.101361.en_US
dc.identifier.issn1018-3647-
dc.identifier.urihttps://bura.brunel.ac.uk/handle/2438/22249-
dc.description.abstract© 2021 The Author(s). In this study, 1-year real life performance of a 30kWp rooftop solar PV power plant installed at the Köprübaşı Vocational School of the Manisa Celal Bayar University was evaluated and is presented here. The PV plant is comprised of 116 polycrystalline modules mounted 15 cm proud of the roof surface providing a gap between roof surface and the bottom of the panels for air circulation. The panels were tilted at 12° with horizontal and orientated at an azimuth angle of -20°. Measured power output of the plant was compared against the predictions of a spreadsheet based simulation model developed. Results were found to be in excellent agreement with the measured values. Annual array yield, final yield and reference yield values of the system that produced 45,592kWh of energy, under an average 1,818kWh/m2/a radiation incident on the panels inclined surfaces, were found to be 4.25, 4.97 and 4.16 h/d, respectively. The annual performance ratio of the system has been calculated as 83.61% and the capacity factor 17.35%. It has been determined that the power plant displaced 23.5 tonnes of CO2 emissions in 2018.en_US
dc.description.sponsorshipZafer Development Agency's project "TR33-16-SUCEP-0028".en_US
dc.format.extent1 - 18-
dc.format.mediumPrint-Electronic-
dc.language.isoen_USen_US
dc.publisherElsevier on behalf of King Saud Universityen_US
dc.rightsPublished under a Creative Commons license.-
dc.rightsCopyright © 2021 The Author(s). Published by Elsevier B.V. on behalf of King Saud University. This is an open access article under a Creative Commons license (https://creativecommons.org/licenses/by/4.0/).-
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/-
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/-
dc.subjectrooftop PVen_US
dc.subjectperformance analysisen_US
dc.subjectsolar energyen_US
dc.subjectphotovoltaicen_US
dc.subjectPVen_US
dc.titleRooftop solar Photovoltaic (PV) plant – one year measured performance and simulationsen_US
dc.typeArticleen_US
dc.identifier.doihttps://doi.org/10.1016/j.jksus.2021.101361-
dc.relation.isPartOfJournal of King Saud University - Science-
pubs.issue3-
pubs.publication-statusPublished-
pubs.volume33-
dc.identifier.eissn2213-686X-
dc.rights.holderThe Author(s)-
Appears in Collections:Dept of Mechanical and Aerospace Engineering Research Papers

Files in This Item:
File Description SizeFormat 
FullText.pdfCopyright © 2021 The Author(s). Published by Elsevier B.V. on behalf of King Saud University. This is an open access article under a Creative Commons license (https://creativecommons.org/licenses/by/4.0/).958.11 kBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons