dc.date.issued2019-07-10-
dc.identifier.citationHacham, W.S. and Khir, A.W. (2019) ‘The speed, reflection and intensity of waves propagating in flexible tubes with aneurysm and stenosis: Experimental investigation’, Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 233(10), pp. 979–988. doi: 10.1177/0954411919859994.en_US
dc.identifier.issn0954-4119-
dc.identifier.urihttps://bura.brunel.ac.uk/handle/2438/21907-
dc.description.abstractA localized stenosis or aneurysm is a discontinuity that presents the pulse wave produced by the contracting heart with a reflection site. However, neither wave speed (c) in these discontinuities nor the size of reflection in relation to the size of the discontinuity has been adequately studied before. Therefore, the aim of this work is to study the propagation of waves traversing flexible tubes in the presence of aneurysm and stenosis in vitro. We manufactured different sized four stenosis and four aneurysm silicone sections, connected one at a time to a flexible ‘mother’ tube, at the inlet of which a single semi-sinusoidal wave was generated. Pressure and velocity were measured simultaneously 25 cm downstream the inlet of the respective mother tube. The wave speed was measured using the PU-loop method in the mother tube and within each discontinuity using the foot-to-foot technique. The stenosis and aneurysm dimensions and c were used to determine the reflection coefficient (R) at each discontinuity. Wave intensity analysis was used to determine the size of the reflected wave. The reflection coefficient increased with the increase and decrease in the size of the aneurysm and stenosis, respectively. c increased and decreased within stenosis and aneurysms, respectively, compared to that of the mother tube. Stenosis and aneurysm induced backward compression and expansion waves, respectively; the size of which was related to the size of the reflection coefficient at each discontinuity, increases with smaller stenosis and larger aneurysms. Wave speed is inversely proportional to the size of the discontinuity, exponentially increases with smaller stenosis and aneurysms and always higher in the stenosis. The size of the compression and expansion reflected wave depends on the size of R, increases with larger aneurysms and smaller stenosis.en_US
dc.language.isoenen_US
dc.publisherSAGE Publicationsen_US
dc.rightsThis article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://www.creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).-
dc.rights.urihttps://www.creativecommons.org/licenses/by-nc/4.0/-
dc.subjectaneurysmen_US
dc.subjectPU-loopen_US
dc.subjectreflection waveen_US
dc.subjectstenosisen_US
dc.subjectwave intensity analysisen_US
dc.titleThe speed, reflection and intensity of waves propagating in flexible tubes with aneurysm and stenosis: experimental investigationen_US
dc.typeArticleen_US
dc.identifier.doihttps://doi.org/10.1177/0954411919859994-
dc.relation.isPartOfProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine-
pubs.issue10-
pubs.publication-statusPublished-
pubs.volume233-
Appears in Collections:Brunel Institute for Bioengineering (BIB)

Files in This Item:
File Description SizeFormat 
FullText.pdf1.44 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons