Please use this identifier to cite or link to this item: http://bura.brunel.ac.uk/handle/2438/21200
Full metadata record
DC FieldValueLanguage
dc.contributor.authorFoda, E-
dc.contributor.authorSirén, K-
dc.date.accessioned2020-07-14T14:45:47Z-
dc.date.available2016-01-01-
dc.date.available2020-07-14T14:45:47Z-
dc.date.issued2014-07-09-
dc.identifier.citationIndoor and Built Environment, 2016, 25 (1), pp. 191 - 202en_US
dc.identifier.issn1420-326X-
dc.identifier.issn1423-0070-
dc.identifier.urihttp://bura.brunel.ac.uk/handle/2438/21200-
dc.description.abstract© International Society of the Built Environment. © The Author(s) 2014. The evaluation of the local thermal comfort and application of thermal manikins can further assist the design and selection of heating systems. This study aimed at evaluating the thermal comfort performance of different heating systems using a newly developed thermal manikin with an enhanced thermal control. The heating systems for a workstation, included a conventional radiator (convector) mounted under the window, heated floor in the occupied zone and an infrared heater mounted to the ceiling. The experiments were conducted in a test room with a façade attached to a climate chamber to simulate outdoor winter conditions. In these experiments, the supplied power for the different systems was kept constant to independently quantify the differences in their thermal comfort performance at same energy consumption. The thermal manikin was deployed in the occupied zone to evaluate the local and overall thermal comfort under each system using the equivalent temperature (Teq) approach. The thermoregulatory control used in the manikin operation is based on a model of human thermoregulation that interacts accurately with the surrounding environment through real-time measurements. The results showed that at the same energy consumption of the different systems, the variations in local thermal comfort levels were up to 1 on the comfort scale.en_US
dc.format.extent191 - 202-
dc.language.isoenen_US
dc.publisherSAGE Publicationsen_US
dc.subjectThermal comforten_US
dc.subjectThermal manikinen_US
dc.subjectHeating systemsen_US
dc.subjectHuman thermoregulationen_US
dc.subjectEquivalent temperatureen_US
dc.titleEvaluating the thermal comfort performance of heating systems using a thermal manikin with human thermoregulatory controlen_US
dc.typeArticleen_US
dc.identifier.doihttp://dx.doi.org/10.1177/1420326X14541822-
dc.relation.isPartOfIndoor and Built Environment-
pubs.issue1-
pubs.publication-statusPublished-
pubs.volume25-
dc.identifier.eissn1423-0070-
Appears in Collections:Dept of Mechanical and Aerospace Engineering Research Papers

Files in This Item:
File Description SizeFormat 
FullText.pdf815.45 kBAdobe PDFView/Open


Items in BURA are protected by copyright, with all rights reserved, unless otherwise indicated.