Please use this identifier to cite or link to this item: http://bura.brunel.ac.uk/handle/2438/18358
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSadrawi, M-
dc.contributor.authorLin, C-H-
dc.contributor.authorLin, Y-T-
dc.contributor.authorHsieh, Y-
dc.contributor.authorKuo, C-C-
dc.contributor.authorChien, J-
dc.contributor.authorHaraikawa, K-
dc.contributor.authorAbbod, M-
dc.contributor.authorShieh, J-S-
dc.date.accessioned2019-06-07T13:50:23Z-
dc.date.available2017-10-25-
dc.date.available2019-06-07T13:50:23Z-
dc.date.issued2017-10-25-
dc.identifier.citationSensors, 2017, 17 (11), pp. 2445 - 2445en_US
dc.identifier.issn1424-8220-
dc.identifier.issnhttp://dx.doi.org/10.3390/s17112445-
dc.identifier.urihttp://bura.brunel.ac.uk/handle/2438/18358-
dc.description.abstractThis study evaluates four databases from PhysioNet: The American Heart Association database (AHADB), Creighton University Ventricular Tachyarrhythmia database (CUDB), MIT-BIH Arrhythmia database (MITDB), and MIT-BIH Noise Stress Test database (NSTDB). The ANSI/AAMI EC57:2012 is used for the evaluation of the algorithms for the supraventricular ectopic beat (SVEB), ventricular ectopic beat (VEB), atrial fibrillation (AF), and ventricular fibrillation (VF) via the evaluation of the sensitivity, positive predictivity and false positive rate. Sample entropy, fast Fourier transform (FFT), and multilayer perceptron neural network with backpropagation training algorithm are selected for the integrated detection algorithms. For this study, the result for SVEB has some improvements compared to a previous study that also utilized ANSI/AAMI EC57. In further, VEB sensitivity and positive predictivity gross evaluations have greater than 80%, except for the positive predictivity of the NSTDB database. For AF gross evaluation of MITDB database, the results show very good classification, excluding the episode sensitivity. In advanced, for VF gross evaluation, the episode sensitivity and positive predictivity for the AHADB, MITDB, and CUDB, have greater than 80%, except for MITDB episode positive predictivity, which is 75%. The achieved results show that the proposed integrated SVEB, VEB, AF, and VF detection algorithm has an accurate classification according to ANSI/AAMI EC57:2012. In conclusion, the proposed integrated detection algorithm can achieve good accuracy in comparison with other previous studies. Furthermore, more advanced algorithms and hardware devices should be performed in future for arrhythmia detection and evaluation.en_US
dc.description.sponsorshipCal-Comp Electronics & Communications Co., Ltd.; Kinpo Electronics, Inc. New Taipei City, Taiwan. Innovation Center for Big Data and Digital Convergence; Yuan Ze University, Taiwan.en_US
dc.format.extent2445 - 2445-
dc.language.isoenen_US
dc.publisherMDPIen_US
dc.subjectwearable sensoren_US
dc.subjectarrhythmiaen_US
dc.subjectsample entropyen_US
dc.subjectfast Fourier transformen_US
dc.subjectartificial neural networksen_US
dc.titleArrhythmia Evaluation in Wearable ECG Devicesen_US
dc.typeArticleen_US
dc.identifier.doihttp://dx.doi.org/10.3390/s17112445-
dc.relation.isPartOfSensors-
pubs.issue11-
pubs.publication-statusPublished-
pubs.volume17-
Appears in Collections:Dept of Electronic and Electrical Engineering Research Papers

Files in This Item:
File Description SizeFormat 
FullText.pdf2.98 MBAdobe PDFView/Open


Items in BURA are protected by copyright, with all rights reserved, unless otherwise indicated.