Please use this identifier to cite or link to this item: http://bura.brunel.ac.uk/handle/2438/18047
Full metadata record
DC FieldValueLanguage
dc.contributor.authorThompson, SG-
dc.contributor.authorBown, MJ-
dc.contributor.authorGlover, MJ-
dc.contributor.authorJones, E-
dc.contributor.authorMasconi, KL-
dc.contributor.authorMichaels, JA-
dc.contributor.authorPowell, JT-
dc.contributor.authorUlug, P-
dc.contributor.authorSweeting, MJ-
dc.date.accessioned2019-05-10T11:55:10Z-
dc.date.available2018-08-01-
dc.date.available2019-05-10T11:55:10Z-
dc.date.issued2018-08-
dc.identifierhttp://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=WOS:000442250700001&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=f12c8c83318cf2733e615e54d9ed7ad5-
dc.identifierhttp://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=WOS:000442250700001&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=f12c8c83318cf2733e615e54d9ed7ad5-
dc.identifier.citationHEALTH TECHNOLOGY ASSESSMENT, 2018, 22 (43), pp. 1 - + (143)en_US
dc.identifier.issnhttp://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=WOS:000442250700001&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=f12c8c83318cf2733e615e54d9ed7ad5-
dc.identifier.issnhttp://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=WOS:000442250700001&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=f12c8c83318cf2733e615e54d9ed7ad5-
dc.identifier.issnhttp://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=WOS:000442250700001&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=f12c8c83318cf2733e615e54d9ed7ad5-
dc.identifier.issnhttp://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=WOS:000442250700001&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=f12c8c83318cf2733e615e54d9ed7ad5-
dc.identifier.issnhttp://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=WOS:000442250700001&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=f12c8c83318cf2733e615e54d9ed7ad5-
dc.identifier.issnhttp://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=WOS:000442250700001&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=f12c8c83318cf2733e615e54d9ed7ad5-
dc.identifier.issn1366-5278-
dc.identifier.issnhttp://dx.doi.org/10.3310/hta22430-
dc.identifier.issn2046-4924-
dc.identifier.issnhttp://dx.doi.org/10.3310/hta22430-
dc.identifier.issn2046-4924-
dc.identifier.issnhttp://dx.doi.org/10.3310/hta22430-
dc.identifier.issn2046-4924-
dc.identifier.urihttp://bura.brunel.ac.uk/handle/2438/18047-
dc.description.abstractBackground Abdominal aortic aneurysm (AAA) screening programmes have been established for men in the UK to reduce deaths from AAA rupture. Whether or not screening should be extended to women is uncertain. Objective To evaluate the cost-effectiveness of population screening for AAAs in women and compare a range of screening options. Design A discrete event simulation (DES) model was developed to provide a clinically realistic model of screening, surveillance, and elective and emergency AAA repair operations. Input parameters specifically for women were employed. The model was run for 10 million women, with parameter uncertainty addressed by probabilistic and deterministic sensitivity analyses. Setting Population screening in the UK. Participants Women aged ≥ 65 years, followed up to the age of 95 years. Interventions Invitation to ultrasound screening, followed by surveillance for small AAAs and elective surgical repair for large AAAs. Main outcome measures Number of operations undertaken, AAA-related mortality, quality-adjusted life-years (QALYs), NHS costs and cost-effectiveness with annual discounting. Data sources AAA surveillance data, National Vascular Registry, Hospital Episode Statistics, trials of elective and emergency AAA surgery, and the NHS Abdominal Aortic Aneurysm Screening Programme (NAAASP). Review methods Systematic reviews of AAA prevalence and, for elective operations, suitability for endovascular aneurysm repair, non-intervention rates, operative mortality and literature reviews for other parameters. Results The prevalence of AAAs (aortic diameter of ≥ 3.0 cm) was estimated as 0.43% in women aged 65 years and 1.15% at age 75 years. The corresponding attendance rates following invitation to screening were estimated as 73% and 62%, respectively. The base-case model adopted the same age at screening (65 years), definition of an AAA (diameter of ≥ 3.0 cm), surveillance intervals (1 year for AAAs with diameter of 3.0–4.4 cm, 3 months for AAAs with diameter of 4.5–5.4 cm) and AAA diameter for consideration of surgery (5.5 cm) as in NAAASP for men. Per woman invited to screening, the estimated gain in QALYs was 0.00110, and the incremental cost was £33.99. This gave an incremental cost-effectiveness ratio (ICER) of £31,000 per QALY gained. The corresponding incremental net monetary benefit at a threshold of £20,000 per QALY gained was –£12.03 (95% uncertainty interval –£27.88 to £22.12). Almost no sensitivity analyses brought the ICER below £20,000 per QALY gained; an exception was doubling the AAA prevalence to 0.86%, which resulted in an ICER of £13,000. Alternative screening options (increasing the screening age to 70 years, lowering the threshold for considering surgery to diameters of 5.0 cm or 4.5 cm, lowering the diameter defining an AAA in women to 2.5 cm and lengthening the surveillance intervals for the smallest AAAs) did not bring the ICER below £20,000 per QALY gained when considered either singly or in combination. Limitations The model for women was not directly validated against empirical data. Some parameters were poorly estimated, potentially lacking relevance or unavailable for women. Conclusion The accepted criteria for a population-based AAA screening programme in women are not currently met.en_US
dc.description.sponsorshipThe National Institute for Health Research Health Technology Assessment programme.en_US
dc.format.extent1 - + (143)-
dc.languageEnglish-
dc.language.isoenen_US
dc.publisherNIHR JOURNALS LIBRARYen_US
dc.subjectScience & Technologyen_US
dc.subjectLife Sciences & Biomedicineen_US
dc.subjectHealth Care Sciences & Servicesen_US
dc.subjectRANDOMIZED-CONTROLLED-TRIALen_US
dc.subjectINDIVIDUAL-PATIENT DATAen_US
dc.subjectOPEN REPAIRen_US
dc.subjectENDOVASCULAR REPAIRen_US
dc.subjectCOST-EFFECTIVENESSen_US
dc.subjectCOMPUTED-TOMOGRAPHYen_US
dc.subjectRISK-FACTORSen_US
dc.subjectPERIOPERATIVE MORTALITYen_US
dc.subjectELECTIVE INTERVENTIONSen_US
dc.subjectSURVEILLANCE INTERVALSen_US
dc.titleScreening women aged 65 years or over for abdominal aortic aneurysm: a modelling study and health economic evaluationen_US
dc.typeArticleen_US
dc.identifier.doihttp://dx.doi.org/10.3310/hta22430-
dc.relation.isPartOfHEALTH TECHNOLOGY ASSESSMENT-
pubs.issue43-
pubs.publication-statusPublished-
pubs.volume22-
dc.identifier.eissn2046-4924-
Appears in Collections:Dept of Health Sciences Research Papers

Files in This Item:
File Description SizeFormat 
FullText.pdf2.92 MBAdobe PDFView/Open


Items in BURA are protected by copyright, with all rights reserved, unless otherwise indicated.