Please use this identifier to cite or link to this item: http://bura.brunel.ac.uk/handle/2438/16550
Title: Structural health monitoring of above-ground storage tank floors by ultrasonic guidedwave excitation on the tank wall
Authors: Lowe, PS
Duan, W
Kanfoud, J
Gan, TH
Keywords: ultrasonic guided waves;above-ground storage tanks;tank floor inspection;non-destructive testing
Issue Date: 2017
Publisher: MDPI
Citation: Sensors (Switzerland), 2017, 17 (11)
Abstract: Abstract: There is an increasing interest in using ultrasonic guided waves to assess the structural degradation of above-ground storage tank floors. This is a non-invasive and economically viable means of assessing structural degradation. Above-ground storage tank floors are ageing assets which need to be inspected periodically to avoid structural failure. At present, normal-stress type transducers are bonded to the tank annular chime to generate a force field in the thickness direction of the floor and excite fundamental symmetric and asymmetric Lamb modes. However, the majority of above-ground storage tanks in use have no annular chime due to a simplified design and/or have a degraded chime due to corrosion. This means that transducers cannot be mounted on the chime to assess structural health according to the present technology, and the market share of structural health monitoring of above-ground storage tank floors using ultrasonic guided wave is thus limited. Therefore, the present study investigates the potential of using the tank wall to bond the transducer instead of the tank annular chime. Both normal and shear type transducers were investigated numerically, and results were validated using a 4.1 m diameter above-ground storage tank. The study results show shear mode type transducers bonded to the tank wall can be used to assess the structural health of the above-ground tank floors using an ultrasonic guided wave. It is also shown that for the cases studied there is a 7.4 dB signal-to-noise ratio improvement at 45 kHz for the guided wave excitation on the tank wall using shear mode transducers.
URI: http://bura.brunel.ac.uk/handle/2438/16550
DOI: http://dx.doi.org/10.3390/s17112542
ISSN: 1424-8220
http://dx.doi.org/10.3390/s17112542
Appears in Collections:Dept of Mechanical and Aerospace Engineering Research Papers

Files in This Item:
File Description SizeFormat 
Fulltext.pdf4.69 MBAdobe PDFView/Open


Items in BURA are protected by copyright, with all rights reserved, unless otherwise indicated.