Please use this identifier to cite or link to this item: http://bura.brunel.ac.uk/handle/2438/15739
Title: Experimental Study on the Stability of the Transmission Tower with Hybrid Slab Foundation
Authors: Yuan, G
Yang, B
Huang, Z
Tan, X
Keywords: Power transmission tower;Hybrid slab foundation;Ground movements;Scaled tower model
Issue Date: 2018
Publisher: ELSEVIER
Citation: Engineering Structures
Abstract: In this paper, a 1:5 scaled tower model for a typical 220 kV single-circuit power transmission tower with hybrid slab foundation has been designed and tested. The scaled tower model was tested under the movement of horizontal ground surface stretching with normal working loading conditions. One of the main objectives of this research is to investigate the stability of the power transmission tower subjected to horizontal ground movement by using hybrid slab foundation. The deformations of the tested tower model and stresses and strains within the different structural members of the tower and the reinforced concrete slab of the foundation have been fully measured. A large mount comprehensive test data has been generated. The research clearly indicated that compared to the isolated tower leg’s foundation the proposed hybrid slab foundation has very good resistance, in terms of truss members’ deformations and stresses, to the ground movement.
URI: http://bura.brunel.ac.uk/handle/2438/15739
ISSN: 0141-0296
Appears in Collections:Dept of Mechanical and Aerospace Engineering Embargoed Research Papers

Files in This Item:
File Description SizeFormat 
Fulltext.pdf24 month embargo until 25/01/20201.89 MBAdobe PDFView/Open


Items in BURA are protected by copyright, with all rights reserved, unless otherwise indicated.