Please use this identifier to cite or link to this item: http://bura.brunel.ac.uk/handle/2438/13697
Title: Active fault-tolerant control for an internet-based networked three-tank system
Authors: He, X
Wang, Z
Qin, L
Zhou, D
Keywords: Active fault-tolerant control (FTC);Actuator failure;Controller reconfiguration;Internet-based networked three-tank system (INTTS);Random packet dropout
Issue Date: 2016
Publisher: Institute of Electrical and Electronics Engineers (IEEE)
Citation: IEEE Transactions on Control Systems Technology, 24 (6): pp. 2150 - 2157, (2016)
Abstract: This brief is concerned with the active fault-tolerant control (FTC) problem for an Internet-based networked three-tank system (INTTS) serving as a benchmark system for evaluating networked FTC algorithms. The INTTS has two parts located at Tsinghua University in China and at the University of South Wales in the U.K., respectively, which are connected via the Internet. With the INTTS as an experimental platform, the active FTC problem is investigated for a class of nonlinear networked systems subject to partial actuator failures. Once a specific actuator failure is detected and confirmed by a fault diagnosis unit, the control law is then reconfigured based on the information of the detected fault. Both the stability and the acceptable H∞ disturbance attenuation level are guaranteed for the closed-loop system using the remaining reliable actuators. Extensive experiments are carried out on the active FTC problem of the INTTS with partial actuator failures, and the effectiveness of the proposed scheme is illustrated.
URI: http://bura.brunel.ac.uk/handle/2438/13697
DOI: http://dx.doi.org/10.1109/TCST.2016.2524595
ISSN: 1063-6536
Appears in Collections:Dept of Computer Science Research Papers

Files in This Item:
File Description SizeFormat 
FullText.pdf2.45 MBAdobe PDFView/Open


Items in BURA are protected by copyright, with all rights reserved, unless otherwise indicated.