Please use this identifier to cite or link to this item: http://bura.brunel.ac.uk/handle/2438/13429
Title: High temperature shear horizontal electromagnetic acoustic transducer for guided wave inspection
Authors: Kogia, M
Gan, T-H
Balachandran, W
Livadas, M
Kappatos, V
Szabo, I
Mohimi, A
Round, A
Keywords: Electromagnetic Acoustic Transducers;EMAT;Guided Wave Testing;High temperature inspection
Issue Date: 2016
Citation: Sensors, 16 (4), 582 (2016)
Abstract: Guided Wave Testing (GWT) using novel Electromagnetic Acoustic Transducers (EMATs) is proposed for the inspection of large structures operating at high temperatures. To date, high temperature EMATs have been developed only for thickness measurements and they are not suitable for GWT. A pair of water-cooled EMATs capable of exciting and receiving Shear Horizontal (SH0) waves for GWT with optimal high temperature properties (up to 500 °C) has been developed. Thermal and Computational Fluid Dynamic (CFD) simulations of the EMAT design have been performed and experimentally validated. The optimal thermal EMAT design, material selection and operating conditions were calculated. The EMAT was successfully tested regarding its thermal and GWT performance from ambient temperature to 500 °C.
URI: http://bura.brunel.ac.uk/handle/2438/13429
DOI: http://dx.doi.org/10.3390/s16040582
ISSN: 1424-8220
Appears in Collections:Dept of Mechanical and Aerospace Engineering Research Papers