Please use this identifier to cite or link to this item: http://bura.brunel.ac.uk/handle/2438/10992
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSaithna, A-
dc.contributor.authorChizari, M-
dc.contributor.authorMorris, G-
dc.contributor.authorAnley, C-
dc.contributor.authorWang, B-
dc.contributor.authorSnow, M-
dc.date.accessioned2015-06-10T13:47:20Z-
dc.date.accessioned2015-06-10T14:03:24Z-
dc.date.available2015-07-01-
dc.date.available2015-06-10T14:03:24Z-
dc.date.issued2015-
dc.identifier.citationClinical Biomechanics, 30(6): 551 - 557, (July 2015)en_US
dc.identifier.issn0268-0033-
dc.identifier.issn1879-1271-
dc.identifier.urihttp://www.sciencedirect.com/science/article/pii/S0268003315001138#-
dc.identifier.urihttp://bura.brunel.ac.uk/handle/2438/10992-
dc.description.abstractBackground This study aimed to evaluate the differences in biomechanical properties of biceps tenodesis when performed with sheathed versus unsheathed screws and also to investigate the effect of altering the pre-tension. Methods Tenodesis was performed in an in vitro model using biomechanical test blocks and ovine tendons. Blocks were allocated to 1 of 5 groups which varied by method of tenodesis and cyclical loading protocol: Group A, Biosure PK screw (10-100 N), Group B: 7-8 mm Biosure Sync and Biosure PK screw (10-100 N), Group C: Biosure PK screw (10-70 N), Group D: Biosure PK (20-100 N), and Group E: custom sheath and Biosure PK screw (10-100 N). If tenodeses remained intact after 500 cycles maximum load to failure testing was performed. Findings 30% of tenodeses in Group A failed prior to 500 cycles whereas none failed in the sheathed device groups (P = 0.02). Using a sheathed device prevented mal-rotation. However, tenodeses in Group B were more likely to fail immediately distal to the tenodesis at a load below the anticipated maximum load to failure suggesting tendon damage during fixation. Using the custom sheath, which did not have sharp edges, resulted in a statistically significant increased maximum load to failure in Group E (348 N) when compared to Group A (228 N, mean difference 120 N, P = 0.01) and Group B (253 N, mean difference 95 N, P = 0.0007). Interpretation Sheathed devices prevent mal-rotation and increase stiffness and maximum load to failure. This is further improved by reducing tendon damage at the time of tenodesis.en_US
dc.description.sponsorshipThis study was supported by funding from The Royal Orthopaedic Hospital Research Grant Committee, The Royal Orthopaedic Hospital, Bristol Road South, Northfield, Birmingham, West Midlands, B31 2AP, UK. This studywas also supported by an Educational Grant of Equipmentfor Study by Smith and Nephew, Cardinal Park, Godmanchester, Huntingdon, Cambridgeshire, PE29 2SN. No funding was received. This grant provided Ultrabraid Suture, Biosure PK screws, Biosure Sync Devices and the instrumentation required for these implants only.en_US
dc.format.extent551 - 557-
dc.languageeng-
dc.language.isoenen_US
dc.publisherElsevier Ltden_US
dc.subjectBiceps tenodesisen_US
dc.subjectBiomechanicsen_US
dc.subjectInterference screwen_US
dc.subjectSheathed deviceen_US
dc.titleAn analysis of the biomechanics of interference screw fixation and sheathed devices for biceps tenodesisen_US
dc.typeArticleen_US
dc.identifier.doihttp://dx.doi.org/10.1016/j.clinbiomech.2015.04.006-
dc.relation.isPartOfClinical Biomechanics-
pubs.issue6-
pubs.issue6-
pubs.issue6-
pubs.issue6-
pubs.volume30-
pubs.volume30-
pubs.volume30-
pubs.volume30-
Appears in Collections:Dept of Mechanical and Aerospace Engineering Research Papers

Files in This Item:
File Description SizeFormat 
Fulltext.pdf618.33 kBAdobe PDFView/Open


Items in BURA are protected by copyright, with all rights reserved, unless otherwise indicated.